Laser ablation Mn/Ca ratios of single foraminiferal shells from the Gulf of Lions

Datacite citation style:
Reichart, Gert-Jan; Ní Fhlaithearta, S. (Shauna); Fontanier, C. (Christophe); Jorissen, F. (Frans); Mouret, A. (Aurélia) et. al. (2018): Laser ablation Mn/Ca ratios of single foraminiferal shells from the Gulf of Lions. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/uuid:9f44c16a-ccc1-4bef-8e98-d01320797271
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
usage stats
967
views
354
downloads
categories
geolocation
Gulf of Lion
lat (N): 43
lon (E): 4
view on openstreetmap
time coverage
2006/2010
licence
cc-0.png logo CC0
Foraminiferal trace element concentrations were determined using two laser ablation ICP-MS systems. Prior to laser ablation, all samples were gently cleaned in methanol (x1) and UHQ water (x4). Between each rinse, the samples were placed in a sonic bath for several seconds to thoroughly clean the tests. Benthic foraminifera from 745m (station D), 980m (station C), 1488m (station B), and 1987m (station A) were measured at Utrecht University using a deep UV (193 nm) ArF excimer laser (Lambda Physik) with GeoLas 200Q optics. Ablation was performed at a pulse repetition rate of 10 Hz and an energy density of 1.4 J/cm², with a crater size of 80 μm. Ablated particles were measured by a quadrupole ICP-MS (Micromass Platform) equipped with a collision and reaction cell. Such a collision and reaction cell improves carbonate analyses by eliminating interferences on mass 44. Scanned masses included 24Mg, 26Mg, 27Al, 42Ca, 43Ca, 55Mn, 88Sr, 137Ba, 138Ba, and 208Pb. Benthic foraminifera from stations F (350 m) and E (552 m) were analyzed at ETH Zurich (due to laboratory renovations at Utrecht University). The laser type and ablation parameters were identical to those detailed above. The ablated particles were measured using a quadrupole ICP-MS (ELAN 6100 DRC, PerkinElmer). In both cases, calibration was performed using an international standard (NIST610) with Ca as an internal standard (Jochum et al., 2011). The same masses as measured in Utrecht were monitored, in addition to 7Li, 23Na, 47Ti, 60Ni, 61Ni, and 89Y. Interlaboratory compatibility was monitored using a matrix-matched calcite standard. For Mn, reported here, this standard showed a precision better than 3%over all analyses, at ETH and UU, and with an offset of less than 5%from an offline-determined (solution ICP-AES) concentration analyzing discrete subsamples. The matrix-matched standard is routinely included in the analyses and has been monitored since 2010 at Utrecht University. Analytical error (equivalent to 1 sigma), based on repeated measurement of an external standard, was < 5% for reported elements. Each laser ablation measurement was screened for contamination by monitoring Al and Pb. On encountering surface contamination, the data integration interval was adjusted to exclude any Al or Pb enrichment. Cross-plots between Al and Pb versus Mn showed that they are unrelated, confirming the accuracy of the integrations.
history
  • 2018-10-19 first online, published, posted
publisher
4TU.Centre for Research Data
format
media types: application/pdf, application/vnd.ms-excel
organizations
NIOZ Royal Netherlands Institute for Sea Research, Department of Ocean Systems, and Utrecht University

DATA

files (2)