Lifecycle ageing tests on commercial 18650 Li ion cell @ 25°C and 45°C
doi:10.4121/13739296.v1
The doi above is for this specific version of this dataset, which is currently the latest. Newer versions may be published in the future.
For a link that will always point to the latest version, please use
doi: 10.4121/13739296
doi: 10.4121/13739296
Datacite citation style:
Trad, Khiem (2021): Lifecycle ageing tests on commercial 18650 Li ion cell @ 25°C and 45°C. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/13739296.v1
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
Cycling ageing of Li ion 18650 commercial cell (Ni rich positive electrode and Si/Gr based negative electrode).
Each test condition was applied on two cells.
The cells were aged at different C-rates and different environmental temperatures.
The cells were cycled within a 10-90%SOC window. These levels are defined from fresh cells and fixed (i.e. not updated with ageing).
The cycling is regularly interrupted to run a reference test.
More details of the ageing tests can be found in the Everlasting deliverable
https://everlasting-project.eu/wp-content/uploads/2020/03/EVERLASTING_D2.3_final_20200228.pdf
history
- 2021-03-11 first online, published, posted
publisher
4TU.ResearchData
format
csv
data link
https://doi.org/10.4121/14113139
funding
- Electric Vehicle Enhanced Range, Lifetime And Safety Through INGenious battery management (grant code 713771) [more info...] European Commission
organizations
Flemish Institute for Technological Research (VITO), Department of Energy Technology
DATA
files (19)
- 1,616 bytesMD5:
cc4d2ae8ce44852b5051c8d971ece1dd
README_2.txt - 445,417,925 bytesMD5:
2ab3812c7b31a3e18093a1a3235b67fb
Cycl_T25_SOC10-90_Dch0.5C_Ch0.5C_Vito_Cell78_AllData.csv - 434,916,522 bytesMD5:
62ad2374f9c108053451762fcdc24eef
Cycl_T25_SOC10-90_Dch0.5C_Ch0.5C_Vito_Cell79_AllData.csv - 440,784,411 bytesMD5:
5620d0c12cd89cdd6ee5784dfc8d68e3
Cycl_T25_SOC10-90_Dch1.5C_Ch0.5C_Vito_Cell82_AllData.csv - 454,170,195 bytesMD5:
cdcf6a599674d82507f3f435e99956e3
Cycl_T25_SOC10-90_Dch1.5C_Ch0.5C_Vito_Cell83_AllData.csv - 474,677,904 bytesMD5:
b2eefa7eebff3e211641ab4e4a56fe59
Cycl_T25_SOC10-90_Dch1.5C_Ch1.0C_Vito_Cell85_AllData.csv - 406,997,386 bytesMD5:
c5dd98134e464b859e3be12375eaff13
Cycl_T45_SOC10-90_Dch0.5C_Ch0.5C_Vito_Cell63_AllData.csv - 437,806,701 bytesMD5:
6f46612db0ed40f23c580dd2ce3b8281
Cycl_T45_SOC10-90_Dch1.5C_Ch0.5C_Vito_Cell64_AllData.csv - 434,039,614 bytesMD5:
b95ff74c6fce7ecc7d59be35a3787ac3
Cycl_T45_SOC10-90_Dch1.5C_Ch0.5C_Vito_Cell65_AllData.csv - 445,085,241 bytesMD5:
316b2ac1793be123115b04e67030a1a7
Cycl_T45_SOC10-90_Dch1.5C_Ch1.0C_Vito_Cell66_AllData.csv - 668,009,236 bytesMD5:
c442cdc471ecff37327e962996bf422d
DrivingAgeing_T25_SOC10-90_Vito_Cell88_AllData.csv - 526,287,454 bytesMD5:
3fefe1635b61a8162326561f9671b915
DrivingAgeing_T25_SOC10-90_Vito_Cell89_AllData.csv - 676,116,937 bytesMD5:
eebfa445c658fc37f79e16af2bb1e768
DrivingAgeing_T25_SOC70-90_Vito_Cell86_AllData.csv - 652,620,475 bytesMD5:
54126429403cd40e0127fb09a6c4d81e
DrivingAgeing_T25_SOC70-90_Vito_Cell87_AllData.csv - 533,185,249 bytesMD5:
d2fdc6c6cc16d2cd8fa0ff8c0e3dee03
DrivingAgeing_T45_SOC10-90_Vito_Cell71_AllData.csv - 791,469,328 bytesMD5:
a7ffd0090c7a627670f6f94680568f3e
DrivingAgeing_T45_SOC70-90_Vito_Cell68_AllData.csv - 703,145,062 bytesMD5:
c97425e0d6f606075d00496b5564178b
DrivingAgeing_T45_SOC70-90_Vito_Cell69_AllData.csv - 609,727,196 bytesMD5:
4e281d390fca94812d41e295eff6c19f
DrivingAgeingPower_T25_SOC10-90_Vito_Cell91_AllData.csv - 609,727,196 bytesMD5:
4e281d390fca94812d41e295eff6c19f
DrivingAgeingPower_T25_SOC10-90_Vito_Cell91_AllData.csv -
download all files (zip)
9,744,185,648 bytes unzipped