All data measured by interception measurement device in Huewerbach basin

Datacite citation style:
Gerrits, A.M.J.(Miriam) (2011): All data measured by interception measurement device in Huewerbach basin. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/uuid:5094d96d-a74c-40b9-8d2b-54b1dd8f3241
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
Delft University of Technology logo
usage stats
720
views
geolocation
Huewelerbach basin interception measurement location
lat (N): 49.71560
lon (E): 5.88802
view on openstreetmap
Measuring instrument: Huewelerbach basin: Interception measurement device According to original data the location is Westerbork NL but this is probably wrong Evaporation measument. Area basin 1.00 m2, 2x3 strain gauges: type FLA-6, resistance 120 Ohm. Valve (< 18 jan 2006): electronic magnetic valve Type: MBMG2Z-1263008-12V. (KOBOLD Instrumentatie BV, Arnhem) Valve (>=18 jan 2006): electronic magnetic valve (12VDC) Type: MBMG2Z-1264020. Messing 3/4 " (KOBOLD Instrumentatie BV, Arnhem) Temperature sensor: LM335, output 10 mV/K (Farnell). Throughfall: tipping bucket & pluvio meters.
history
  • 2011-09-19 first online, published, posted
publisher
4TU.Centre for Research Data
format
media types: application/x-netcdf
organizations
TU Delft, Faculty of Civil Engineering and Geosciences
contributors
  • Durr, E.H.(Eugene)