PAR006 Optical disdrometer data at Slufter
DOI: 10.4121/4f06f599-5b16-42d1-b0d1-5fe976fc3f2c
Datacite citation style
Dataset
Usage statistics
Geolocation
Time coverage 2022-2024
Licence CC BY 4.0
Interoperability
Description: In-situ measurements of raindrop size distributions, fall velocities, drop number concentrations and surface rain rates recorded by an OTT Parsivel2 disdrometer named "PAR006" in Slufter, The Netherlands. Located in the Maasvlakte Rotterdam, The Slufter is a large-scale storage site for contaminated sludge in the southwestern part of the Rotterdam Maasvlakte, approximately 31 km West of the city center of Rotterdam. Along the ring dike of the Slufter, several wind turbines belong to the Windpark Slufterdam are providing electricity for the region. The same site also features a micro-rain radar "MRR005_Slufter" (since March 2022). All sensors are placed on top of an air quality monitoring container belonging to TNO, at a height of approx. 4 meters. The rough climate conditions near the coast of the North Sea, with high winds, salt, and sand creates a very challenging environment for long-term weather observations. Consequently, data availability tends to be lower than at other sites, due to frequent maintenance and technical issues.
Format: Each NetCDF file covers a full month of observations. The temporal resolution is 1 minute. Data are provided "as is", without any post-processing. The NetCDF files contain all relevant information about all the variables, attributes and units. The global attributes of the NetCDF files contain important information about the type of sensor, logging software, project contributors and history of the dataset. If a monthly file is missing, no data are available for this month.
Relevance: Optical disdrometer data are useful for studying the type, dynamics and microphysics of precipitation from the perspective of a fixed observer on the ground. The data can be used to help calibrate weather radars, improve quantitative precipitation estimates, calculate the absorption/attenuation/propagation of electromagnetic signals through the atmosphere, and quantify important physical quantities such as liquid water content, rain amount, intensity and kinetic energy.
Note: The integrated temperature sensor of PAR006 was defective between November 2022 and April 2023. During this period, unrealistic temperatures above 60 degrees were measured . Also, the temperature time series contain some large spikes, suggesting the existence of other (unknown) problems. The temperature sensor was replaced on April 3, 2023. However, some large temperature spikes persisted beyond that period until the whole circuit board failed in November 2023 due to corrosion. The sensor was then sent back to the manufacturer and repaired. Data collection resumed in August 2024.
History
- 2024-10-04 first online, published, posted
Publisher
4TU.ResearchDataFormat
NetCDFFunding
- Ruisdael Observatory (grant code 184.034.015) [more info...] Dutch Research Council (NWO)
Organizations
TU Delft, Faculty of Civil Engineering and Geosciences, Department of Geoscience and Remote SensingDATA
Files (23)
- 1,897 bytesMD5:
7e56d6d9255fa4ad2a748a914a7ca374README.md - 4,525,792 bytesMD5:
f20f7362804b71cde3e685cf51a3a072PAR006_Slufter_202203.nc - 4,764,301 bytesMD5:
2730fcc1b0e18ee2aafa34ae356fe938PAR006_Slufter_202204.nc - 4,658,339 bytesMD5:
858ba163057536a654a7328b70411cc6PAR006_Slufter_202205.nc - 4,767,600 bytesMD5:
3dde94fe56ae3c955a644623337562dePAR006_Slufter_202206.nc - 4,713,507 bytesMD5:
c149ee8f90c6ff24289b8358d8c1ad21PAR006_Slufter_202207.nc - 4,734,820 bytesMD5:
e7aa9d41eb9472af554e620635271ae9PAR006_Slufter_202208.nc - 5,116,957 bytesMD5:
a77febb428d1a667e4c00871f82337c7PAR006_Slufter_202209.nc - 4,480,690 bytesMD5:
3772edfa6b005ea7e495d81981ae1ebaPAR006_Slufter_202210.nc - 5,218,394 bytesMD5:
8f0f303f3d998726f70c6abc69c27935PAR006_Slufter_202211.nc - 4,419,576 bytesMD5:
fc0525fd3eff8489b0a61fdfaefc2472PAR006_Slufter_202212.nc - 4,862,322 bytesMD5:
1ba96120420d7c2ce21a345b3ed7d4dcPAR006_Slufter_202301.nc - 4,036,354 bytesMD5:
e2a297fd3838ead4c347685f2a445206PAR006_Slufter_202302.nc - 4,767,730 bytesMD5:
56fe739b30252f258e9654dc978cce05PAR006_Slufter_202303.nc - 4,852,117 bytesMD5:
6fc224227666bb2657cbbf00f214f238PAR006_Slufter_202304.nc - 4,817,551 bytesMD5:
25cdcfe63574ba47fb936c2431e92d92PAR006_Slufter_202305.nc - 4,379,888 bytesMD5:
24c5d4b50b82ad178e9a568e0789d7c8PAR006_Slufter_202306.nc - 5,142,572 bytesMD5:
401c37c8428d57200a9952ca4fb7bc14PAR006_Slufter_202307.nc - 5,122,533 bytesMD5:
4f288d5871974936b7da8c0aca8dc4c9PAR006_Slufter_202308.nc - 4,825,421 bytesMD5:
8fdca9879b3f1d09d4304f391bb0e66cPAR006_Slufter_202309.nc - 5,578,898 bytesMD5:
2e20fc2d7a0acda7c3c93d1362d92140PAR006_Slufter_202310.nc - 5,072,723 bytesMD5:
c5127f0e47bcb84c6f37ceac2fce72eePAR006_Slufter_202311.nc - 4,489,471 bytesMD5:
92c4960dc5972709b354922963026e38PAR006_Slufter_202408.nc -
download all files (zip)
105,349,453 bytes unzipped





