Data underlying the publication: Sizing batteries for power flow management in distribution grids
doi:10.4121/4a9dac6d-dd4e-4dc2-a5ba-72e35d86ac93.v2
The doi above is for this specific version of this dataset, which is currently the latest. Newer versions may be published in the future.
For a link that will always point to the latest version, please use
doi: 10.4121/4a9dac6d-dd4e-4dc2-a5ba-72e35d86ac93
doi: 10.4121/4a9dac6d-dd4e-4dc2-a5ba-72e35d86ac93
Datacite citation style:
van Someren, Christian (2023): Data underlying the publication: Sizing batteries for power flow management in distribution grids. Version 2. 4TU.ResearchData. dataset. https://doi.org/10.4121/4a9dac6d-dd4e-4dc2-a5ba-72e35d86ac93.v2
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
choose version:
version 2 - 2023-11-21 (latest)
version 1 - 2023-10-11
Includes the following datasets:
- The IEEE Test Grid Excel file which is read into the Python model to generate the test grid (.xlsx file).
- Load Patterns used for consumer connections in the Python model, with variable simultaneity (simultaneity % is indicated after the '_' in the file name) (.csv files).
- A generation pattern file used in the Python model. The file is currently filled with 0's, but can be adapted to test decentral generation effects (.csv file).
- The final results and data analysis (.xlsm file).
Also included is the .py file with the code used to simulate power flows in the grid.
This work is supported by Hanze University of Applied Sciences.
history
- 2023-10-11 first online
- 2023-11-21 published, posted
publisher
4TU.ResearchData
associated peer-reviewed publication
Sizing Batteries for Power Flow Management in Distribution Grids: A Method to Compare Battery Capacities for Different Siting Configurations and Variable Power Flow Simultaneity
references
funding
- [more info...] Hanze University of Applied Sciences
organizations
TU Eindhoven, Department of Electrical Engine
DATA
files (11)
- 2,708 bytesMD5:
0f32918d87288ab90f3a871f44ec392e
Readme_Data underlying Sizing of batteries for power flow management.txt - 27,503 bytesMD5:
6ddc7f3e70d6a2dba84b86853907ad4e
Battery Sizing Model.py - 354,181 bytesMD5:
15653373b52a0a9d966ad5879512d91f
Final Results_05102023.xlsm - 10,815 bytesMD5:
b60cb99fa481230b316bc4ff73f2b163
Generation Pattern.csv - 85,056 bytesMD5:
4b203bdd6ae44b2446bad065cd73498a
IEEE Test Grid.xlsx - 11,915 bytesMD5:
5d182309634bf5c4106ed635b13861e8
LoadPattern_30.csv - 11,915 bytesMD5:
24418fffa6760a9939d0774ef9cf5c22
LoadPattern_40.csv - 11,915 bytesMD5:
b33a029ec51fb723451b46ee7c307981
LoadPattern_50.csv - 11,915 bytesMD5:
14e84d6dcb0c7de23a876ffc81fbd165
LoadPattern_60.csv - 11,915 bytesMD5:
d87c19e64734408b83ebb74e85e9294f
LoadPattern_70.csv - 11,915 bytesMD5:
af71abf990afae6bc90bd9c87cebaa2e
LoadPattern_80.csv -
download all files (zip)
551,753 bytes unzipped