Measured data from sensor Q1 at Maisbich for month 2008-01
Datacite citation style:
Luxemburg, W.M.J.(Wim); van den Dool, Cees-Anton (2009): Measured data from sensor Q1 at Maisbich for month 2008-01. Version 1. 4TU.ResearchData. dataset. https://doi.org/10.4121/uuid:2eacb9d5-ab0a-4985-855d-2e446e098c99
Other citation styles (APA, Harvard, MLA, Vancouver, Chicago, IEEE) available at Datacite
Dataset
Usage statistics
1012
views
5
downloads
Geolocation
Maisbich basin: V-notch discharge meter Q1
lat (N): 49.8820
lon (E): 6.0468
view on openstreetmap
Time coverage 2008-01
Licence 4TU General Terms of Use
Collection
Parent item:
Maisbich (Luxemburg), measured data from discharge meter Q1, 2003-12 to 2008-05
Measuring instrument:
Maisbich basin: V-notch discharge meter Q1
Type: Pressure Sensor Keller DCX-4.0, SN 1454
This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature.
Height of V-notch above sensor: hV=0.145m.
The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff).
History
- 2009-11-03 first online, published, posted
Publisher
4TU.Centre for Research DataFormat
media types: application/x-netcdf, text/xmlOrganizations
TU Delft, Faculty of Civil Engineering and GeosciencesContributors
- Durr, E.H.(Eugene)
OPeNDAP data service