TY - DATA T1 - Calculated data from sensor Q1 at Maisbich for month 2004-06 PY - 2009/10/08 AU - W.M.J.(Wim) Luxemburg AU - Cees-Anton van den Dool UR - https://data.4tu.nl/articles/dataset/Calculated_data_from_sensor_Q1_at_Maisbich_for_month_2004-06/12719126/1 DO - 10.4121/uuid:f8965245-0986-4878-a495-8e27f11e8574 N2 - Height notch above sensor 0.145m Parent item: Maisbich (Luxemburg), calculated data from discharge meter Q1, 2003-12 to 2008-05 Measuring instrument: Maisbich basin: V-notch discharge meter Q1 Type: Pressure Sensor Keller DCX-4.0, SN 1454 This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature. Height of V-notch above sensor: hV=0.145m. The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff). Contributor: Durr, E.H.(Eugene) ER -