%0 Generic
%A Wiersma, Myrthe
%A Heiles, Baptiste
%A Kalisvaart, Dylan
%A Maresca, David
%A Smith, Carlas
%D 2022
%T Data underlying the publication: Retrieving pulsatility in ultrasound localization microscopy
%U https://data.4tu.nl/articles/dataset/Data_underlying_the_publication_Retrieving_pulsatility_in_ultrasound_localization_microscopy/21517878/1
%R 10.4121/21517878.v1
%K ultrasound imaging
%K ultrasound localization microscopy
%K pulsatility
%K localization precision
%K velocity distribution
%K Location awareness
%K trajectory
%K Ultrasonic imaging
%K Imaging
%K Frequency control
%X
General information
This simulation data belongs to the article:
Retrieving pulsatility in ultrasound localization microscopy
DOI: 10.1109/OJUFFC.2022.3221354
This information is also available in README.txt, included in this repository.
Code availability
The scripts that should be used to process this data can be found at: https://github.com/qnano/ulm-pulsatility
Data description
The simulation data in this repository, is contained in several .zip files:
- DataSetFig3.zip: This dataset contains the simulation data needed to reproduce Fig. 3 of the article.
- DataSetR1.zip: This dataset contains the simulation data corresponding to the lateral vessel location R1. It is needed to reproduce Fig 4 and Fig. 6b.
- DataSetR2.zip: This dataset contains the simulation data corresponding to the lateral vessel location R2. It is needed to reproduce Fig 4 and Fig. 6b.
- DataSetR3.zip: This dataset contains the simulation data corresponding to the lateral vessel location R3. It is needed to reproduce Fig 4 and Fig. 6b.
The .zip folders contain the following:
- LOTUS_INPUT: This folder contains the input simulated ultrasound images, of which the file names are parametrized as:
- chunk***.mat: Data set containing IQ variable of size 180x240x1000, containing 1000 B-mode images of dimension 9mmx12mm
- ULM_results: This folder is initially empty. Results of running the scripts will be stored in this folder.
- PAR.mat: Parameters with which the ultrasound images are simulated. See scripts for further details.
- TOTAL_MB.mat: Contains the variable MB_loc_conc that describes the simulated (ground truth) location of the MBs at each frame (z, x) [mm].
- Saved MB tracks used for visualization. One of the following options:
- RAW_tracks.mat
- Track_r1_illustration.mat
- Track_r2_illustration.mat
- Track_r3_illustration.mat
- GT_theta.mat: Ground truth orientation of the simulated vessels
- velAv.mat: Average velocity in the simulated vessels during the simulation.
Download the desired .zip file and see the documentation at https://github.com/qnano/ulm-pulsatility for instructions on processing the data.
%I 4TU.ResearchData