%0 Generic %A Luxemburg, W.M.J.(Wim) %A van den Dool, Cees-Anton %D 2011 %T Maisbich (Luxemburg), calculated data from discharge meter Q1, 2003-12 to 2008-05 %U https://data.4tu.nl/articles/dataset/Maisbich_Luxemburg_calculated_data_from_discharge_meter_Q1_2003-12_to_2008-05/12715625/1 %R 10.4121/uuid:ccf40267-fe28-465c-ad0a-c2c8d1676fee %X Measuring instrument: Maisbich basin: V-notch discharge meter Q1 Type: Pressure Sensor Keller DCX-4.0, SN 1454 This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature. Height of V-notch above sensor: hV=0.145m. The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff).
Contributor: Durr, E.H.(Eugene)
%I 4TU.Centre for Research Data