%0 Generic
%A Luxemburg, W.M.J.(Wim)
%A Westhoff, M.C.(Martijn)
%D 2009
%T Measured/calculated data from sensor Q1 at Maisbich for month 2008-08
%U https://data.4tu.nl/articles/dataset/Measured_calculated_data_from_sensor_Q1_at_Maisbich_for_month_2008-08/12712883/1
%R 10.4121/uuid:af5c01d0-41fc-4a47-86e6-ed4525ecaae0
%K climate
%K discharge
%K hydrology
%K river basin
%X Parent item:
Maisbich (Luxemburg), data from discharge meter Q1, 2008-06 and later
Measuring instrument:
Maisbich basin: V-notch discharge meter Q1
Type: Pressure Sensor Keller DCX-4.0, SN 1454
This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature.
Height of V-notch above sensor: hV=0.145m.
The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff).
%I 4TU.Centre for Research Data