%0 Generic %A Luxemburg, W.M.J.(Wim) %A Westhoff, M.C.(Martijn) %D 2009 %T Measured/calculated data from sensor Q1 at Maisbich for month 2008-08 %U https://data.4tu.nl/articles/dataset/Measured_calculated_data_from_sensor_Q1_at_Maisbich_for_month_2008-08/12712883/1 %R 10.4121/uuid:af5c01d0-41fc-4a47-86e6-ed4525ecaae0 %K climate %K discharge %K hydrology %K river basin %X Parent item: Maisbich (Luxemburg), data from discharge meter Q1, 2008-06 and later Measuring instrument: Maisbich basin: V-notch discharge meter Q1 Type: Pressure Sensor Keller DCX-4.0, SN 1454 This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature. Height of V-notch above sensor: hV=0.145m. The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff). %I 4TU.Centre for Research Data