%0 Generic %A Luxemburg, W.M.J.(Wim) %A van den Dool, Cees-Anton %D 2009 %T Calculated data from sensor Q1 at Maisbich for month 2005-11 %U https://data.4tu.nl/articles/dataset/Calculated_data_from_sensor_Q1_at_Maisbich_for_month_2005-11/12719276/1 %R 10.4121/uuid:faba4a77-f58b-4272-b61c-48a0aaa17521 %X Values missing between 11-01 and 11-18 Height V-notch above sensor0.145m Parent item: Maisbich (Luxemburg), calculated data from discharge meter Q1, 2003-12 to 2008-05 Measuring instrument: Maisbich basin: V-notch discharge meter Q1 Type: Pressure Sensor Keller DCX-4.0, SN 1454 This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature. Height of V-notch above sensor: hV=0.145m. The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff). Contributor: Durr, E.H.(Eugene) %I 4TU.Centre for Research Data