cff-version: 1.2.0 abstract: "Cycling ageing of Li ion 18650 commercial cell (Ni rich positive electrode and Si/Gr based negative electrode).Each test condition was applied on two cells.
The cells were aged at different C-rates and different environmental temperatures.The cells were cycled within a 10-90%SOC window. These levels are defined from fresh cells and fixed (i.e. not updated with ageing).The cycling is regularly interrupted to run a reference test.More details of the ageing tests can be found in the Everlasting deliverable https://everlasting-project.eu/wp-content/uploads/2020/03/EVERLASTING_D2.3_final_20200228.pdf " authors: - family-names: Trad given-names: Khiem orcid: "https://orcid.org/0000-0002-4959-2006" title: "Lifecycle ageing tests on commercial 18650 Li ion cell @ 25°C and 45°C" keywords: version: 1 identifiers: - type: doi value: 10.4121/13739296.v1 license: CC BY-NC 4.0 date-released: 2021-03-11