File(s) can be accessed via the link:
Calculated data from sensor Q1 at Maisbich for month 2005-01
dataset
posted on 2009-10-08, 00:00 authored by W.M.J.(Wim) Luxemburg, Cees-Anton van den DoolHeight V-notch above sensor0.145m
Parent item:
Maisbich (Luxemburg), calculated data from discharge meter Q1, 2003-12 to 2008-05
Measuring instrument:
Maisbich basin: V-notch discharge meter Q1
Type: Pressure Sensor Keller DCX-4.0, SN 1454
This instrument is based on differential pressure measurement of two absolute sensors. The sensors measure pressure and temperature.
Height of V-notch above sensor: hV=0.145m.
The discharge is calculated with the rating curve Q=C*(h-hV)^2.5 where C is a calibration constant and h results from the pressure difference (Willem Luxemburg, Martijn Westhoff).
Contributor: Durr, E.H.(Eugene)